Photometrics Driver Download



Multi Channel Photometric Converter

The C4000 converter is a multi channel controller capable of operating all optek photometric sensors. The C4000 converter allows for easy programming and operation, and can supply up to four real time configurable 4-20 mA output values correlated to any units of measure. The C4000 offers configurable relay alarms, can record and download process data, and can operate up to four sensors simultaneously.

    Used For

  • For UV, VIS, NIR Absorption sensors
  • Color scales:
    • APHA / HAZEN / Pt/Co color
    • AOCS (Method Cc 13b-45) color
    • ASTM (D1500) color
    • EBC color
    • ASBC color
    • Gardner (ASTM D1544) color
    • ICUMSA color
    • KLETT color
    • Reference Base Unit (RBU, color)
    • Saybolt (ASTM D 156, D 6045) color
  • Turbidity scales:
    • CU (concentration units)
    • ppm (DE)
    • FTU
    • NTU
    • FAU
    • EBC

LED Module & Driver Specs; LED Platform, Tower & Driver Specs; Emergency Driver Specifications; Sensors, Photocells & Receptacles; Installation Instructions. StreamPix supports optiMOS, CoolSnap CF, HQ, ES, EZ, FX, Cascade 128+, Cascade 1k, Cascade II 512, Cascade II 1024, SenSys, QuantEM, Prime BSI. PVCAM works across all Teledyne Photometrics products and takes under 5 minutes to install on any PC running Windows or Linux. In addition to the driver, PVCAM contains two advanced applications that will be immediately ready for use on the host computer. Download Photometrics for iOS to the ARRI Photometric App gives you the ability to quickly reference the photometric characteristics of all of the ARRI light fixtures.The following.

The Control 4000 photometric converter is designed for optek ultraviolet (UV), visible (VIS), near-infrared (NIR) absorption based and scattered light based sensors. The graphic display can show absorbance, transmittance and concentration in real-time and in any unit of measure such as CU, OD, %-Tr., ppm (DE), EBC, FTU, g/L and many others.

Display Modes

  • 1 - 4 simultaneously displayed values (configurable)
  • Numeric with bar graph and alarm setting
  • Trendline

Remote Control

  • Parameter set (e. g. range)
  • Zero
  • Hold

Software Tools

  • 8 parameter sets (incl. range, alarm, display, etc.)
  • 16 linearization tables (max. 11 points)
  • 8 offset and slope sets
  • Auto zero (local or remotely activated)
  • Factory zero (scattered light sensors only)
  • Password protection (3 levels and none)
  • Memory (non-volatile) retains all configurations and logged data
Benefits
4 channel photometric measurement converter and 2 signal inputs
Connect up to 4 photometric sensors and 2 analogue devices (e.g., pressure / temperature compensation in gas measurement)
Menu based software in serveral languages including linearization curve options
Easy configuration of the converter for individual applications
Can be installed in hazardous areas saving additional installation costs

Photometrics Driver Download Windows 7

Graphics display for up to 4 real time measurements
Free editable measurement formats and multiple data display and output capabilities
Optional Profibus®PA and FOUNDATION™Fieldbus connectivity
Easy implementation of data communication into Bus-Environment
C4000
Housing

19'-version for mounting in control cabinets 3 U / 42 HP

dimensions:W 213.0 mm (8.39 in.) H 128.4 mm (5.06 in.) D 230.0 mm (9.05 in.)

material:stainless steel / polyester / silicone / glass / diverse plastics

protection:front IP40 / rear IP20 (mains supply secured against accidental touching)

Display

LCD graphic display black on white (240 x 128 pixel), LED background illuminated

Operation

18-button keyboard

System clock

accuracy approx. 1 minute/month (battery life approx. 15 years)

LED

1 LED (green):power on

1 LED (red-flashing):system failure

3 LEDs (yellow):alarm I, II, III

Data logger

4 parallel measuring values

(ring buffer with approx. 25,000 data points x 4)

(interval: 1/second - 1/hour)

Sensor-inputs

1 - 4 for optek photometric sensors

Sensor-inputs
(explosion proof)

optional:1 - 4 for optek photometric sensors (intrinsic safe)

mA-inputs

optional:

2 x 4 - 20 mA (functionally galvanically isolated)

accuracy:< 0.5 %

resolution:< 0.05 %

load:< 200 Ohm

Remote-inputs

optional:7 x 24 V (19 ... 29 V DC),
typically 6.0 mA for remote range setting, remote zero, remote hold

Profibus® PA interface

optional:

Profibus® PA profile, version 3.01, amendment 2

FOUNDATION™ Fieldbus interface

optional:

FOUNDATION™ Fieldbus H1 (IEC 61158-2)

Sensor lamp-outputs

1 or 2 lamp supply for optek photometric sensors

4.5 ... 8.5 V DC

mA-outputs

2 or 4 x 0/4 - 20 mA (NAMUR)

(functionally galvanically isolated)

accuracy:< 0.5 %

resolution:< 0.05 %

load:< 600 Ohm

Relay-outputs

3 independent software-configurable relay contacts

0 - 50 V AC, 0 - 75 V DC, 0 - 2 A

for alarm or status feedback

initiation delay configurable: 0 - 999 sec.

Failsafe-output

1 SPDT contact to alarm in case of lamp or system failure (active)

0 - 50 V AC, 0 - 75 V DC, 0 - 2 A

Serial communication

RS232 bi-directional interface on front panel (with software package optek PC-transfer)

upload / download of configuration, download of data logger content

Cable lengths
(sensor)

2, 3, 5, 10, 15, 20, 30 ... 100 m

(7, 10, 16, 33, 49, 66, 98 ... 328 ft)

cable length > 100 m on request up to 1,000 m (3,280 ft)

sensors: AS56 / AS16: max: 50 m

sensors: ASD: 2, 3, 5 or 10 m (7, 10, 16 or 33 ft.)

Power supply

115 / 230 V AC, selectable (93.5 - 132 / 187 - 264 V AC, 47 - 64 Hz) or 24 V AC / DC (AC: 20.4 - 26.4 V AC, 47 - 64 Hz; DC: 20.4 - 28.8 V DC)

power consumption:< 50 VA

Ambient conditions

temperature during operation (no direct sunlight):

converter: -10 - 55 °C (14 - 131 °F)

with optional stainless steel housing S19-42 (IP65): -20 - 45 °C ( -4 - 113 °F)

with optional plastic housing B19-42 (IP66): -10 - 40 °C (14 - 104 °F) (C4000 only)

with optional Ex D housing (IP65): -20 - 40 °C ( -4 - 104 °F) (C4000 only)

temperature during transport (no direct sunlight): -20 - 70 °C ( -4 - 158 °F)

Software languages

English, German, French, Spanish, Dutch, Portuguese, Russian

Data given are subject to changes without prior notice.
SensorC4000 Configurations
12344101 4121 4151 41614201 4221 4251 42614202 4222 4252 4262 4422 4452 4462
AF16 (AS16)---
AF16 (AS16)AF16 (AS16)----
AF16 (AS16)AF26 or AF45 or TF16-----
AF26----
AF26AF26 or AF45 or TF16-----
AF45----
AF45AF45 or TF16-----
AF46------
TF16----
TF16TF16-----
ASD12 or ASD25---
ASD12 or ASD25ASD12 or ASD25---
ASD12 or ASD25ASD12 or ASD25ASD12 or ASD25----
ASD12 or ASD25ASD12 or ASD25ASD12 or ASD25ASD12 or ASD25---
C4000 Configurations4101420142024121422142224422
1Detector inputs (optek)1221224
2Power supply 115/230 or 24 V
3Remote-IN: (Zero, Range, Hold)---
4Relay-outputs3333333
Failsafe-relay (active)
5Lamp output (optek)1121122
6mA-outputs (0/4 - 20 mA)2242244
7mA-inputs (4 - 20 mA)---2222
pH-probe- (with C8000 only)
Conductivity (optek ACF)- (with C8000 only)
Ex-proof (optional)

PROFIBUS® PA

  • Fulfills application profile for process automation (version 3.01)
  • Cyclic:
    • 4 measuring outputs, each with 4x limit and status
    • Status of all 4 relays
    • 2 measuring inputs
  • Acyclic:
    • Zero, Hold, Product change, Monitors, Error codes
  • GSD, EDD file and DTM for FDT interface provided
  • Interface to profibus DP segment using a segment coupler
Photometrics Driver Download

FOUNDATION™ Fieldbus

  • Fulfills FOUNDATION™ Fieldbus H1 (IEC 61158-2)
  • Registered function blocks: 1xRB, 8xAI(s), 4xDI(s), 2xAO(s)
  • H1 Profile class: 31P, 32L
  • H1 Device class: basic, link master
  • 4 Measuring outputs with status (C8000 8 measuring outputs with status)
  • 4 Relays with status (C8000 1 Relay with status)
  • 2 Measuring inputs (only C4000)
  • With optek specific resource block parameter: Zero, Hold, Product change
  • Device description (DD) and capabilities files provided
C4000 Configurations
8PROFIBUS® PA4151425142524452
FOUNDATION™ Fieldbus4161426142624462
1Detector inputs (optek)1224
2Power supply 115/230 or 24 V
3Remote-IN: (Zero, Range, Hold)----
4Relay-outputs3333
Failsafe-relay (active)
5Lamp output (optek)1122
6mA-outputs (0/4 - 20 mA)2244
7mA-inputs (4 - 20 mA)----
pH-probe- (with C8000 only)
Conductivity (optek ACF)- (with C8000 only)
Ex-proof (optional)

Front panel Mounting Kit for series C4000, C8000, HazeControl

PN: 1200-3321-0001-00

Wall mount housing B19-42 for 1 converter C4000, HazeControl or for 2 converters X56

Photometrics Driver Download Windows 10

PN: 1200-3321-0002-00

Wall mount housing S19-42 for 1 converter C4000, C8000, HazeControl or for 2 converters X56

PN: 1200-3321-0003-00

C4000 - C8000 Product Information

Photometrics Driver Download Software

Visit our documentation page to view a complete list of translated documents.

Photometrics Driver Download Pc

Call Us:
Germany
+49-(0)201-63409-0
United States
+1-262-437-3600
Singapore
+65-6562-8292
China