Multi Channel Photometric Converter
The C4000 converter is a multi channel controller capable of operating all optek photometric sensors. The C4000 converter allows for easy programming and operation, and can supply up to four real time configurable 4-20 mA output values correlated to any units of measure. The C4000 offers configurable relay alarms, can record and download process data, and can operate up to four sensors simultaneously.
- For UV, VIS, NIR Absorption sensors
- Color scales:
- APHA / HAZEN / Pt/Co color
- AOCS (Method Cc 13b-45) color
- ASTM (D1500) color
- EBC color
- ASBC color
- Gardner (ASTM D1544) color
- ICUMSA color
- KLETT color
- Reference Base Unit (RBU, color)
- Saybolt (ASTM D 156, D 6045) color
- Turbidity scales:
- CU (concentration units)
- ppm (DE)
- FTU
- NTU
- FAU
- EBC
Used For
LED Module & Driver Specs; LED Platform, Tower & Driver Specs; Emergency Driver Specifications; Sensors, Photocells & Receptacles; Installation Instructions. StreamPix supports optiMOS, CoolSnap CF, HQ, ES, EZ, FX, Cascade 128+, Cascade 1k, Cascade II 512, Cascade II 1024, SenSys, QuantEM, Prime BSI. PVCAM works across all Teledyne Photometrics products and takes under 5 minutes to install on any PC running Windows or Linux. In addition to the driver, PVCAM contains two advanced applications that will be immediately ready for use on the host computer. Download Photometrics for iOS to the ARRI Photometric App gives you the ability to quickly reference the photometric characteristics of all of the ARRI light fixtures.The following.
The Control 4000 photometric converter is designed for optek ultraviolet (UV), visible (VIS), near-infrared (NIR) absorption based and scattered light based sensors. The graphic display can show absorbance, transmittance and concentration in real-time and in any unit of measure such as CU, OD, %-Tr., ppm (DE), EBC, FTU, g/L and many others.
Display Modes
- 1 - 4 simultaneously displayed values (configurable)
- Numeric with bar graph and alarm setting
- Trendline
Remote Control
- Parameter set (e. g. range)
- Zero
- Hold
Software Tools
- 8 parameter sets (incl. range, alarm, display, etc.)
- 16 linearization tables (max. 11 points)
- 8 offset and slope sets
- Auto zero (local or remotely activated)
- Factory zero (scattered light sensors only)
- Password protection (3 levels and none)
- Memory (non-volatile) retains all configurations and logged data
Photometrics Driver Download Windows 7
C4000 | ||
---|---|---|
Housing | 19'-version for mounting in control cabinets 3 U / 42 HP dimensions:W 213.0 mm (8.39 in.) H 128.4 mm (5.06 in.) D 230.0 mm (9.05 in.) material:stainless steel / polyester / silicone / glass / diverse plastics protection:front IP40 / rear IP20 (mains supply secured against accidental touching) | |
Display | LCD graphic display black on white (240 x 128 pixel), LED background illuminated | |
Operation | 18-button keyboard | |
System clock | accuracy approx. 1 minute/month (battery life approx. 15 years) | |
LED | 1 LED (green):power on 1 LED (red-flashing):system failure 3 LEDs (yellow):alarm I, II, III | |
Data logger | 4 parallel measuring values (ring buffer with approx. 25,000 data points x 4) (interval: 1/second - 1/hour) | |
Sensor-inputs | 1 - 4 for optek photometric sensors | |
Sensor-inputs (explosion proof) | optional:1 - 4 for optek photometric sensors (intrinsic safe) | |
mA-inputs | optional: 2 x 4 - 20 mA (functionally galvanically isolated) accuracy:< 0.5 % resolution:< 0.05 % load:< 200 Ohm | |
Remote-inputs | optional:7 x 24 V (19 ... 29 V DC), | |
Profibus® PA interface | optional: Profibus® PA profile, version 3.01, amendment 2 | |
FOUNDATION™ Fieldbus interface | optional: FOUNDATION™ Fieldbus H1 (IEC 61158-2) | |
Sensor lamp-outputs | 1 or 2 lamp supply for optek photometric sensors 4.5 ... 8.5 V DC | |
mA-outputs | 2 or 4 x 0/4 - 20 mA (NAMUR) (functionally galvanically isolated) accuracy:< 0.5 % resolution:< 0.05 % load:< 600 Ohm | |
Relay-outputs | 3 independent software-configurable relay contacts 0 - 50 V AC, 0 - 75 V DC, 0 - 2 A for alarm or status feedback initiation delay configurable: 0 - 999 sec. | |
Failsafe-output | 1 SPDT contact to alarm in case of lamp or system failure (active) 0 - 50 V AC, 0 - 75 V DC, 0 - 2 A | |
Serial communication | RS232 bi-directional interface on front panel (with software package optek PC-transfer) upload / download of configuration, download of data logger content | |
Cable lengths (sensor) | 2, 3, 5, 10, 15, 20, 30 ... 100 m (7, 10, 16, 33, 49, 66, 98 ... 328 ft) cable length > 100 m on request up to 1,000 m (3,280 ft) sensors: AS56 / AS16: max: 50 m sensors: ASD: 2, 3, 5 or 10 m (7, 10, 16 or 33 ft.) | |
Power supply | 115 / 230 V AC, selectable (93.5 - 132 / 187 - 264 V AC, 47 - 64 Hz) or 24 V AC / DC (AC: 20.4 - 26.4 V AC, 47 - 64 Hz; DC: 20.4 - 28.8 V DC) power consumption:< 50 VA | |
Ambient conditions | temperature during operation (no direct sunlight): converter: -10 - 55 °C (14 - 131 °F) with optional stainless steel housing S19-42 (IP65): -20 - 45 °C ( -4 - 113 °F) with optional plastic housing B19-42 (IP66): -10 - 40 °C (14 - 104 °F) (C4000 only) with optional Ex D housing (IP65): -20 - 40 °C ( -4 - 104 °F) (C4000 only) temperature during transport (no direct sunlight): -20 - 70 °C ( -4 - 158 °F) | |
Software languages | English, German, French, Spanish, Dutch, Portuguese, Russian | |
Data given are subject to changes without prior notice. |
Sensor | C4000 Configurations | ||||||
---|---|---|---|---|---|---|---|
1 | 2 | 3 | 4 | 4101 4121 4151 4161 | 4201 4221 4251 4261 | 4202 4222 4252 4262 | 4422 4452 4462 |
AF16 (AS16) | - | - | - | ||||
AF16 (AS16) | AF16 (AS16) | - | - | - | - | ||
AF16 (AS16) | AF26 or AF45 or TF16 | - | - | - | - | - | |
AF26 | - | - | - | - | |||
AF26 | AF26 or AF45 or TF16 | - | - | - | - | - | |
AF45 | - | - | - | - | |||
AF45 | AF45 or TF16 | - | - | - | - | - | |
AF46 | - | - | - | - | - | - | |
TF16 | - | - | - | - | |||
TF16 | TF16 | - | - | - | - | - | |
ASD12 or ASD25 | - | - | - | ||||
ASD12 or ASD25 | ASD12 or ASD25 | - | - | - | |||
ASD12 or ASD25 | ASD12 or ASD25 | ASD12 or ASD25 | - | - | - | - | |
ASD12 or ASD25 | ASD12 or ASD25 | ASD12 or ASD25 | ASD12 or ASD25 | - | - | - |
C4000 Configurations | 4101 | 4201 | 4202 | 4121 | 4221 | 4222 | 4422 | |
---|---|---|---|---|---|---|---|---|
1 | Detector inputs (optek) | 1 | 2 | 2 | 1 | 2 | 2 | 4 |
2 | Power supply 115/230 or 24 V | |||||||
3 | Remote-IN: (Zero, Range, Hold) | - | - | - | ||||
4 | Relay-outputs | 3 | 3 | 3 | 3 | 3 | 3 | 3 |
Failsafe-relay (active) | ||||||||
5 | Lamp output (optek) | 1 | 1 | 2 | 1 | 1 | 2 | 2 |
6 | mA-outputs (0/4 - 20 mA) | 2 | 2 | 4 | 2 | 2 | 4 | 4 |
7 | mA-inputs (4 - 20 mA) | - | - | - | 2 | 2 | 2 | 2 |
pH-probe | - (with C8000 only) | |||||||
Conductivity (optek ACF) | - (with C8000 only) | |||||||
Ex-proof (optional) |
PROFIBUS® PA
- Fulfills application profile for process automation (version 3.01)
- Cyclic:
- 4 measuring outputs, each with 4x limit and status
- Status of all 4 relays
- 2 measuring inputs
- Acyclic:
- Zero, Hold, Product change, Monitors, Error codes
- GSD, EDD file and DTM for FDT interface provided
- Interface to profibus DP segment using a segment coupler
FOUNDATION™ Fieldbus
- Fulfills FOUNDATION™ Fieldbus H1 (IEC 61158-2)
- Registered function blocks: 1xRB, 8xAI(s), 4xDI(s), 2xAO(s)
- H1 Profile class: 31P, 32L
- H1 Device class: basic, link master
- 4 Measuring outputs with status (C8000 8 measuring outputs with status)
- 4 Relays with status (C8000 1 Relay with status)
- 2 Measuring inputs (only C4000)
- With optek specific resource block parameter: Zero, Hold, Product change
- Device description (DD) and capabilities files provided
C4000 Configurations | |||||
---|---|---|---|---|---|
8 | PROFIBUS® PA | 4151 | 4251 | 4252 | 4452 |
FOUNDATION™ Fieldbus | 4161 | 4261 | 4262 | 4462 | |
1 | Detector inputs (optek) | 1 | 2 | 2 | 4 |
2 | Power supply 115/230 or 24 V | ||||
3 | Remote-IN: (Zero, Range, Hold) | - | - | - | - |
4 | Relay-outputs | 3 | 3 | 3 | 3 |
Failsafe-relay (active) | |||||
5 | Lamp output (optek) | 1 | 1 | 2 | 2 |
6 | mA-outputs (0/4 - 20 mA) | 2 | 2 | 4 | 4 |
7 | mA-inputs (4 - 20 mA) | - | - | - | - |
pH-probe | - (with C8000 only) | ||||
Conductivity (optek ACF) | - (with C8000 only) | ||||
Ex-proof (optional) |
Front panel Mounting Kit for series C4000, C8000, HazeControl
PN: 1200-3321-0001-00
Wall mount housing B19-42 for 1 converter C4000, HazeControl or for 2 converters X56
Photometrics Driver Download Windows 10
PN: 1200-3321-0002-00
Wall mount housing S19-42 for 1 converter C4000, C8000, HazeControl or for 2 converters X56
PN: 1200-3321-0003-00
C4000 - C8000 Product Information
Photometrics Driver Download Software
Visit our documentation page to view a complete list of translated documents.
Photometrics Driver Download Pc
- Germany
- +49-(0)201-63409-0
- United States
- +1-262-437-3600
- Singapore
- +65-6562-8292
- China
- +86-21-28986326